COMPREHENSIVE ENGINEERS TEST KIT - ETK005
|
KEY FEATURES
- Ideal for mobile treatment engineers
- Compact & portable design
- Key treatment parameters included:
- Conductivity/TDS (0-19,999µS)
- pH (0.00 - 14.00)
- Alkalinity P (0 - 2400ppm)
- Alkalinity M (0 - 2400ppm)
- Alkalinity OH (0 - 2400ppm)
- Bromine (0 - 5ppm)
- Chlorine (0 - 4ppm)
- Chloride (0 - 3000ppm)
- Hardness Total (0 - 1200ppm)
- Hardness Calcium (0 - 1200ppm)
- Hardness Stop/Go (0 - 4ppm)
- Iron (0 - 1ppm) & (0 - 10ppm)
- Molybdate (0 - 100ppm)
- Nitrite (0 - 2000ppm)
- Phosphate (0 - 80ppm)
- Phosphonate (0 - 20ppm)
- Sulphite (0 - 150ppm)
- Tannin (0 - 300ppm)
Note: Range is dependant on measuring instrument used. |
SYSTEM MONITORING KIT
The DTK Comprehensive Engineers Test Kit has been developed specifically for engineers and treatment professionals responsible for the maintaining and management of boiler systems. This test kit has been designed to include the key parameters which enable the monitoring of samples in these water systems ensuring optimum operating conditions are maintained.
The kit provides accuracy and speed, utilising titration, drop test and comparator methods together with electronic meters for the most efficient monitoring of water samples. The reagents and equipment are specified below.
The ETK005 is supplied in a robust aluminium carry case with reagents and instruments secured and retained by a high quality chemical resistant foam insert with sufficient chemical reagents to carry out between 100 and 200 tests.
INDUSTRIAL WATER TREATMENT
Water systems require regular and careful monitoring to ensure the correct water conditions are maintained. Chemicals are dosed to ensure the integrity and performance of the system. An treatment programme should be specified according to the system and then be maintained in accordance with it. The correct dosing of these treatement chemicals is critical to the success of a treatment program and the long life of the plant.
Any failure to maintain the correct levels and dosing of the chemical treatments can lead to:
- Corrosion of the system (leaks)
- Formation of scale (blocked pipes)
- Increased biological activity
These can lead to unstable water conditions with potential negative consequences to the life of the plant and operating costs. |
TEST KIT & INSTRUMENTS
ORDER CODE |
DESCRIPTION |
PACK SIZE |
ETK005 |
Engineers Test Kit |
ea |
EDT119 |
Jenway 430 Combination Meter |
ea |
EDT022 |
Digital Titrator |
ea |
EDT056 |
Refractometer |
ea |
EDT085 |
Plastic Comparator (Standard) |
ea |
146280 |
Bromine disk |
ea |
146020 |
Chlorine disk |
ea |
146220 |
Iron LR disk |
ea |
146320 |
Iron HR disk |
ea |
146290 |
Molybdate disk |
ea |
146250 |
Phosphate HR disk |
ea |
ACCESSORIES
ORDER CODE |
DESCRIPTION |
PACK SIZE |
EDT084 |
Waterproof Test Instructions |
ea |
EDT082 |
Washer Bottle |
ea |
EDT018 |
125ml Plastic Test Bottle |
ea |
EDT018 |
65ml Plastic Test Bottle |
ea |
EDT075 |
20ml Plastic Syringe |
ea |
EDT073 |
10ml Plastic Syringe |
ea |
EDT077 |
5ml Plastic Syringe |
ea |
EDT074 |
1ml Plastic Syringe |
ea |
EDT044 |
25mm Filter Holder |
ea |
EDT048 |
Filter Papers GF/C (50Pk) |
50Pk |
EDT079 |
Crushing Rod |
ea |
EDT196 |
Cell Cleaning Brush |
ea |
EDT015 |
5 / 10ml Plastic Test Tube |
ea |
EDT023 |
Titration Syringe Assembly |
ea |
|
REAGENT CODES
| ORDER CODE |
DESCRIPTION |
PACK SIZE |
TYPE |
SDT001 |
PA1 - Alkalinity P Indicator |
|
65ml |
DT |
SDT007 |
PA3 - 'OH' Alkalinity |
ea |
65ml |
DT |
SDT004 |
TA4 - Alkalinity M Indicator |
ea |
65ml |
DT |
CART002 |
Alkalinity Cartridge |
ea |
20ml |
DT |
SDT023 |
BC1/CC1 - Chloride Indicator |
ea |
65ml |
DT |
CART003 |
Chloride Cartridge |
ea |
20ml |
DT |
SDT106 |
DPD No.1 Tablets |
ea |
50Pk |
CT |
SDT107 |
DPD No.3 Tablets |
ea |
50Pk |
CT |
SDT131 |
DPD Nitrite Tablets |
ea |
50Pk |
CT |
SDT043 |
CH2 - Calcium Hardness Buffer |
ea |
65ml |
DT |
SDT050 |
CH1P - Calcium Hardness Indicator |
ea |
20g |
DT |
SDT046 |
TH2 - Total Hardness Buffer |
ea |
65ml |
DT |
SDT047 |
TH5 - Total Hardness Indicator |
ea |
65ml |
DT |
CART007 |
Hardness Cartridge |
ea |
20ml |
DT |
SDT129 |
Hardness Stop / Go Solution |
ea |
65ml |
DT |
SDT110 |
FE5 - Iron LR |
ea |
65ml |
CT |
SDT247 |
FE10 - Iron HR |
ea |
65ml |
CT |
SDT127 |
Molybdate HR |
ea |
65ml |
CT |
SDT072 |
N1 - Nitrite Indicator |
ea |
65ml |
DT |
SDT155 |
Sulphuric Acid 50% |
ea |
65ml |
DT |
CART009 |
Nitrite Cartridge |
ea |
20ml |
DT |
SDT163 |
Phosphate HR Tablets |
ea |
50Pk |
CT |
SDT514 |
P1/2 - Indicator/neutraliser |
ea |
65ml |
DT |
SDT080 |
P3 - Phosphonate pH Adjuster |
ea |
65ml |
DT |
SDT291 |
P4L - Phosphonate Indicator |
ea |
65ml |
DT |
CART004 |
Phosphonate Cartridge |
ea |
20ml |
DT |
SDT518 |
S1L - Sulphite Indicator |
ea |
65ml |
DT |
CART005 |
Sulphite Cartridge |
ea |
20ml |
DT |
SDT094 |
TN1 - Taninn Buffer |
ea |
40g |
DT |
SDT095 |
TN2 - Tannin Titrant |
ea |
65ml |
DT |
SDT154 |
Standard Conductivity 12.88mS |
ea |
65ml |
STD |
SDT119 |
pH 4 Buffer Solution |
ea |
65ml |
STD |
SDT118 |
pH 7 Buffer Solution |
ea |
65ml |
STD |
SDT161 |
pH 10 Buffer Solution |
ea |
65ml |
STD |
SDT103 |
Acetic Acid 20% |
ea |
65ml |
STD |
|
| |