Engineers Test Kit with PrimeLab

Eng_Test_Kit_PL_Titration_1000x1000
peli2200stand_500x500

KEY FEATURES

    • Ideal for mobile treatment engineers.
    • Compact & portable design.
    • Key treatment parameters included:
      • Conductivity/TDS (0 to 19,999 µS),
      • pH (0.00 to 14.00),
      • Alkalinity P (0 to 2000 mg/l),
      • Alkalinity M (0 to 2000 mg/l),
      • Alkalinity OH (0 to 2000 mg/l),
      • Bromine (0.05 to 18 mg/l),
      • Chlorine (0.01 to 8 mg/l),
      • Chlorine Dioxide (0.02 to 15 mg/l),
      • Chloride (0 to 2000 mg/l),
      • Hardness Total (0 to 2000 mg/l),
      • Hardness Calcium (0 to 2000 mg/l),
      • Hardness Stop/Go (Hard / Soft),
      • Iron Soluble & Total (0 to 30 mg/l),
      • Molybdate HR (5 to 200 mg/l),
      • Nitrite (0 to 2000 mg/l),
      • Phosphate HR (0 to 100 mg/l),
      • Phosphonate (0 to 20 mg/l),
      • Sulphite (0 to 2000 mg/l),
      • Tannin (10 to 300 mg/l).

Note: Range is dependant on measuring instrument used.

Engineers Test kit with PrimeLab ETK006P

Our Comprehensive combined test kit is based on the PrimeLab photometer and electronic titration gun chemistries and has been devolped as a complete kit, specifically for water treatment professionals involved with the maintenance and management of boiler, cooling water and closed water systems.

Water systems require careful test monitoring to ensure the correct risk management regimes and water treatment programmes are maintained at all times.

Failure to maintain the correct water system conditions can lead to serious problems. These include reduce system efficiency, the build-up of scale, potentially damaging corrosive water conditions and increased microbiological activity, which may result in the proliferation of Legionella bacteria and the increased risks associated with Legionnaries’ disease.

Our Comprehensive combined test kit is presented in its own robust plastic case and includes all the equipment and reagents necessary to effectively test and monitor boiler, cooling and closed system waters to ensure optimum operating conditions are chieved and maintained.

Equipment, Parameters & Reagents

Contents Range Displayed As Code
Large Peli Plastic Case complete with foams PLA109
PrimeLab Photometer c/w Batteries, Manual & Charger PLP001
8 x 10 ml Glass Cells for PrimeLab Photometer PLA100
Refractometer (PEG & MEG) 0 to 60 % EDT056
Maestro Electronic Pipette [1.0 ml] c/w 6 tips EDT387
2 x 20 ml Leur Lock Syringe EDT075
10 ml Leur Lock Syringe EDT073
5 ml Standard Syringe EDT077
1 ml Standard Syringe EDT074
Syringe Filter Holder – Luer Lock ø 25 mm EDT044
GF/C Filter Papers ø 25 mm EDT048
Filter Papers ø 25 mm 0.45 µm (50 pk) EDT061
125 ml Plastic Test Bottle EDT008
5 ml Standard Syringe EDT077
LED Torch EDT008
4 x 65 ml Plastic Test Bottle EDT018
Tablet Crusher EDT079
Cell CLeaning Brush EDT196
White Testing Board N/A
LED Torch EDT008
5/10ml Tube c/w Screw Top EDT018
2 x 250 ml Plastic Wide Neck Bottle EDT011
250 ml Washer Bottle EDT082
250 ml Plastic Beaker EDT098
Combined pH/Conductivity/TDS & Temp Meter DTK2017
Alkalinity P (Titration)
0 to 2000
mg/l CaCO3
PA1 (65 ml) SDT001
Alkalinity Titrant [Cartridge Strength] (65 ml) CART002-65
Alkalinity M (Titration) 0 to 2000 mg/l CaCO3
TA4 (65 ml) (also uses Alkalinity Titrant) SDT004
Alkalinity OH (Titration) 0 to 2000 mg/l CaCO3
PA3 (65 ml) (also uses Alkalinity Titrant & PA1) SDT007
Bromine (Photometer) 0.05 to 18 mg/l Br2
PL DPD 1 A (30 ml) PLR102
PL DPD 1 B (30 ml) PLR103
PL DPD Nitrite Powder (20 g) PLR108
Chloride (Titration) 0 to 2000 mg/l Cl
BC1/CC1 (65 ml) SDT023
Chloride Titrant [Cartridge Strength] (65 ml) CART003-65
Chlorine (Photometer) 0.01 to 8 mg/l Cl2
PL DPD No 3 Solution C (30 ml) (also uses PL DPD 1 A & B) PLR104
Chlorine Dioxide (Photometer) 0.01 to 8 mg/l Cl2
PL DPD Glycine C (30 ml) (also uses PL DPD 1 A & B) PLR106
Hardness Total, (Titration) 0 to 2000 mg/l CaCO3
TH2 (65 ml) SDT046
TH5 (65 ml) SDT047
Hardness HR Titrant [Cartridge Strength] (65 ml) CART007-65
Hardness Calcium, (Titration) 0 to 2000 mg/l CaCO3
CH2 (65 ml) SDT043
CH1P (20 g) (also requires TH3 & H/TH4/CH3) SDT050
Hardness Stop/Go (Drop Test) Hard/Soft
Hardness Stop/Go Solution (65 ml) SDT129
Iron Soluble & Total (Photometer) 0 to 30 mg/l Fe
PL Iron HR 1 (65 ml) PLR119
PL Iron HR 2 (30 ml) PLR120
Molybdate HR (Photometer) 5 to 200 mg/l MoO4
PL Molybdate 1 (65 ml) SDT127
Nitrite (Titration) 10 to 2000 mg/l NaNO2
N1 (65 ml) SDT072
Nitrite Titrant [Cartridge Strength] (65 ml) CART009-65
Sulphuric Acid 50% (65 ml) SDT155
Phosphate HR (Photometer) 0 to 100 mg/l PO4
PL Phosphate HR 1 (65 ml) PLR129
PL Phosphate HR 2 (65 ml) PLR130
Phosphonate (Titration) 0 to 20 mg/l
P1/2 (65 ml) SDT514-65
P3 (65 ml) SDT080
P4L (65 ml) SDT291
Phosphonate Titrant [Cartridge Strength] (65 ml) CART004-65
Sulphite (Titration) 0 to 2000 Na2SO3
S1 (40 g) SDT092
Sulphite Titrant [Cartridge Strength] (65 ml) CART005-65
Phosphonate Titrant [Cartridge Strength] (65 ml) CART004-65
Tannin (Drop Test) 10 to 300
TN1 (40 g) SDT094
TN2 (65 ml) SDT095
Calibration Solutions for Combined pH, Cond’y & TDS Meter
Standard Conductivity 1413 µs (65 ml) SDT109-65
pH 4 (65 ml) SDT119-65
pH 7 (65 ml) SDT118-65
pH 10 (65 ml) SDT161-65
20% Acetic Acid (65 ml) SDT103

Back to the top.

DTK Water
4 Morris Close,
Park Farm Ind Est,
Wellingborough,
NN8 6XF, UK
T: +44 (0)1604 686995
F: +44 (0)1604 686997
E: info@dtkwater.com