Archive for March, 2014

SEWAGE EFFLUENT TEST KIT

Posted by admin
Sewage_Effluent_Kit_1000x1000
Sewage Effluent Test Kit
 
CHECKTIT-comparator-for-web-square
Comparator

KEY FEATURES

    • Meet legislation & minimise the risks.
    • Compact & portable design.
    • Monitor variety of sewage effluent systems.
    • Real time analysis.
    • Simple to perform tests which require no specialist training.
    • Easy to follow waterproof instructions.
    • Clear product labelling.
    • Wide range of testing capabilities.
    • Permanganate Value (0 – 30+),
    • pH value (4 – 10),
    • Temperature (0 – 50 deg C),
    • Turbidity and Suspended Solids (30 – 500),
    • Indications of probable BOD, COD and TOC (0 – 45mg/l).

FOR SEWAGE EFFLUENT WATER TESTING

The DTK Sewage Effluent Test Kit provides a simple means of monitoring the quality of sewage Effluents. The tests cover the essential quality control checks required for the day to day operation of sewage works and effluent treatment plants.

It is important that the condition of sewage effluent discharges be checked to ensure they conform to consent limits. Similarly the importance of regular testing by sewage works operators as a check on the efficiency of the works is widely recognised.

Sewage Effluent Kits have been developed to meet this need and are particularly useful at sewage works and other locations without full laboratory facilities. Each of the tests is performed simply without the use of complicated equipment and are suitable for operators without formal training in water testing and analysis.

The Sewage Effluent Tests are based on those recommended by the Department of the Environment and the Water Research Centre and accord generally with the methods laid down in “Analysis of Raw, Potable and Waste Waters” published by HMSO.

SIMPLE TO USE AND FULLY PORTABLE

Our test instruction booklet is in full colour and has easy to follow step by step instructions making on site analysis simple.The reagent labels and test booklet are printed on waterproof and chemical resistant paper making them more durable.

TEST KIT & REPLACEMENT CODES

ORDER CODE
DESCRIPTION
PACK SIZE
STK001
Sewage Effluent Test Kit
Kit
EDT085
Plastic Comparator
ea
256130
pH Universal Disk (4 – 10 pH)
ea
EDT028-2
Medium Plastic Case
ea
EDT006-1
2 x 10ml Square Plastic Cell
ea
EDT079
Tablet Crusher
ea
EDT160
3 x Plastic Shaker/Dilution Tube 100ml
ea
39240
Extech Waterproof Stick Thermometer
ea
EDT373
13 Inch Turbidity Tube
ea
SDT713
Permanganate Value Tablets
300pk
SDT714
3 x Acidifying SE Tablets
100pk
SDT710
Universal pH Tablets
100pk
EDT196
Cell Cleaning Brush
ea

 

 

POTABLE WATER TEST KIT

Posted by admin
Potable_Water_Test_Kit_1000x1000
Potable Water Test Kit
image010
Dipslide Incubator

KEY FEATURES

    • Monitor variety of systems on vessels and offshore installations.
    • Minimise the risks to the crew or visitor’s on board.
    • Compact & portable design.
    • Non-compliance or failed inspections can result in vessel detention.
    • Simple to perform tests which require no specialist training.
    • Easy to follow waterproof instructions and clear product labelling.
    • Real time analysis with a wide range of testing capabilities.
    • Biological – Coliform, E.Coli, Pseudomonas Aeruginosa, Enterococci, TVC (Total viable count).
    • Physical – Conductivity, pH, Temperature, TDS, Salinity.
    • Biocides – Chlorine, Chlorine Dioxide.

FOR ONBOARD WATER TESTING

The DTK Potable Water Test Kit has been developed to offer offshore rigs and sea vessels the complete monitoring solution for their water systems, with the option of additional extras if required (i.e. legionella testing, ATP monitoring).

The DTK Potable Water Test Kit ensures compliance to WHO guidelines, ILO 178 (2009), MLC (Maritime Labour Convention, 2006) and IHR (International Health Regulations, 2005) requirements.

The DTK Potable Water Test Kit provides optimum performance from onboard systems or offshore installations. If you need to adhere to current or forthcoming legislation requirements to minimise the risk to the crew or visitors health & Safety on board, we offer the best solution.

The DTK Potable Water Test Kit provides for regular monitoring of bacteria, turbidity, temperature, chlorine, pH, conductivity and total hardness allow the operator to ensure that safe water quality is maintained. Be aware each step in the water transfer chain provides an opportunity for contamination.

SIMPLE TO USE AND FULLY PORTABLE

Our test instruction booklet is in full colour and has easy to follow step by step instructions making on site analysis simple.The reagent labels and test booklet are printed on waterproof and chemical resistant paper making them more durable.

The Potable Water Test Kit requires an incubator for the incubation of dipslides. We recomend using the Discovery 10 however we provide a range of incubators which may better suit your needs. To see the full range click here.

TEST KIT & REPLACEMENT CODES

ORDER CODE
DESCRIPTION
PACK SIZE
PWT001
Potable Water Test Kit
Kit
pH1S
pH/Temp Meter with solutions
ea
EC1S
Conductivity/TDS/Temp Meter with solutions
ea
EDT085
Plastic Comparator
ea
256020
Chlorine LR Disk
ea
EDT026DF
Mini Aluminium Case
ea
D005
TTC / Chromogenic Dipslides
10pk
D007
TTC / Pseudomonas
10pk
EDT006-1
2 x 10ml Square Plastic Cell
ea
EDT079
Tablet Crusher
ea
EDT160
Plastic Shaker/Dilution Tube 100ml
ea
EDT177
10ml Standard Syringe
ea
39240
Extech Waterproof Stick Thermometer
ea
EDT373
26 Inch Turbidity Tube
ea
SDT106-50
DPD No 1 Tablets
50pk
SDT107-50
DPD No 3 Tablets
50pk
SDT530-50
Hardness Total Tablets (Tablet Count)
50pk
SDT109/65
Conductivity Std 1413 µS
65ml
SDT119/65
pH 4 Buffer Solution
65ml
SDT118/65
pH 7 Buffer Solution
65ml
SDT161/65
pH 10 Buffer Solution
65ml

Note: If you require an incubator for Dipslides check out our full range here.

PRIMELAB DOWNLOADS

Posted by admin
downloadbutton

PRIMELAB DESKTOP ASSISTANT

With the Windows software “PrimeLab Desktop Assistant” the PrimeLab connects wirelessly via Bluetooth to your PC and can be managed there.

Download the PrimeLab Desktop Assistant Now!

PRIMELAB BROCHURE

All information about the PrimeLab 1.0 Multitest can be downloaded here, as a PDF.

 Unbenannt-1
instructiondownloadbutton

PRIMELAB INSTRUCTION MANUAL

Download the current operating instructions for the “PrimeLab 1.0 Multitest” and the “PrimeLab Desktop Assistant” as a .pdf file.
The operating instructions comprise all measuring methods described in detail and with additional instructions.
If you prefer a pre-printed user manual in a ring binder please ask for details.

PARAMETERS / REAGENTS

Posted by admin

DECIDE YOURSELF WHICH PARAMETERS YOUR PRIMELAB CAN MEASURE

The advantage of the “JENCOLOR” sensor system is that additional parameters can be downloaded to your PrimeLab remotely at any time before or after purchase. Then with the correct reagents the PrimeLab Photometer is ready to go.

Each parameter is shown with its corresponding reagents. When ordering you will recieve an activation code which will activate the parameter on the PrimeLab unit. You will also receive the necessary reagents for that parameter.

PARAMETERS AVAILABLE AND REAGENT CODES

PARAMETER
RANGE
I.D. / ORDER CODE

PACK SIZE

Active Oxygen (Tablets)
O2
0 – 40 ppm
001
PL
PL DPD No4 Tablets
PLR158/50
50pk
Alkalinity M (Tablets)
CaCO3
5 – 200 ppm
005
PL
PL Total Alkalinity Tablets
 PLR144/50
50pk
Alkalinity P (Tablets)
CaCO3
5 – 300 ppm
006
PL
PL Alkalinity P Tablets
PLR159/50
50pk
Aluminium (Tablets)
Al
0 – 0.3 ppm
004
PL
PL Aluminium No1 Tablets
PLR156/50
50pk
PL Aluminium No2 Tablets
PLR157/50
50pk
Ammonia LR (Tablets)
N
0 – 1 ppm
002
PL
PL Ammonia No1 Powder
PLR100
40g
PL Ammonia No2 Powder
PLR101
40g
Boron (Tablets)
B
0 – 2 ppm
007
PL
PL Boron No1 Tablets
PLR206/50
50pk
PL Boron No2 Tablets
PLR207/50
50pk
Bromine (Tablets)
Br2
0 – 18 ppm
008
PL
PL DPD No1 Tablets
PLR141/50
50pk
PL DPD Glycine Tablets
PLR143/50
50pk
Bromine (Liquids)
Br2
0 – 18 ppm
063
PL
PL DPD No1 Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
PL DPD Nitrite Powder
PLR108
20g
Calcium Hardness (Tablets)
CaCO3 0 – 500 ppm 078 PL
PL Calcium Hardness No1 Tablets
PLR148/50
50pk
PL Calcium Hardness No2 Tablets
PLR149/50
50pk
Calcium Hardness HR (Tablets)
CaCO3 50 – 1000 ppm 009 PL
PL Calcium Hardness Tablets
PLR146/50
50pk
Carbohydrazide (Liquid)
 – 0 – 1.3 ppm 071 PL
PL Oxygen Scavenger No1 Solution
PLR112
30ml
PL Oxygen Scavenger No2 Solution
PLR113
30ml
Chemical Oxygen Demand LR (Pre)
O2 0 – 150 ppm 079 PL
PL COD LR Pre Vial
PLR218
25pk
Chemical Oxygen Demand MR (Pre)
O2 0 – 1500 ppm 080 PL
PL COD MR Pre Vial
PLR219
25pk
Chemical Oxygen Demand HR (pre)
O2 0 – 15000 ppm 017 PL
PL COD HR Pre Vial
PLR220
25pk
Chloramines (Tablets)
 Cl2 0 – 8 ppm 095 PL
PL DPD No1 Tablets
PLR141/50
50pk
PL DPD No2 Tablets
PLR213/50
50pk
PL DPD No3 Tablets
PLR142/50
50pk
Chloride (Tablets)
Cl
0.5 – 25 ppm 010  PL
PL Chloride No1 Tablets
PLR154/50
50pk
PL Chloride No2 Tablets
PLR155/50
50pk
Chlorine Dioxide (Liquids)
ClO2 0 – 15 ppm 064 PL
PL DPD No1 A Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
PL DPD Glycine Solution
PLR106
30ml
Chlorine Dioxide (Tablets)
ClO2 0 – 15 ppm 016 PL
PL DPD No1 Tablets
PLR141/50
50pk
PL DPD Glycine Tablets
PLR143/50
50pk
Chlorine HR (Liquids)
Cl2 0 – 200 ppm 015 PL
PL Chlorine HR No1 Solution
PLR109
30ml
PL Chlorine HR No2 Solution
PLR110
30ml
Chlorine HR (Tablets)
Cl2 5 – 200 ppm 014 PL
PL Chlorine HR Tablets
PLR164/50
50pk
PL Acidifying GP Tablets
PLR165/50
50pk
Chlorine (Liquids)
Cl2 0 – 8 ppm 012 PL
PL DPD No1 A Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
PL DPD No3 C Solution
PLR104
30ml
Chlorine (Tablets)
Cl2 0 – 8 ppm 011 PL
PL DPD No1 Tablets
PLR141/50
50pk
PL DPD No3 Tablets
PLR142/50
50pk
Chlorite (Liquids)
 Cl2 0 – 8 ppm 106 PL
PL DPD Glycine Solution
PLR106
30ml
PL DPD No1 A Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
PL DPD No 3 C Solution
PLR104
30ml
PL DPD Acidifying Solution
PLR105
30ml
PL DPD Neutralising Solution
PLR107
30ml
Chromium (Liquids)
Cr 0 – 1 ppm 103 PL
PL Chromate No1 Powder
PLR188
10g
PL Chromate No2 Solution
PLR189
65ml
Chromium (Tablets)
Cr 0 – 2.2 ppm 094 PL
PL Chromium No1 Tablets
PLR210/50
50pk
PL Chromium No2 Tablets
PLR211/50
50pk
Colour
0 – 500 Pt/Co 107 PL
No Reagents
Copper (Powder)
Cu 0 – 5 ppm 019 PL
PL Copper No1 Powder
PLR111
20g
Copper (Tablets)
Cu  0 – 5 ppm 018 PL
PL Copper No1 Tablets
PLR166/50
50pk
PL Copper No2 Tablets
PLR167/50
50pk
Cyanuric Acid (Tablets)
C3H3N3O3 2 – 160 ppm 020 PL
PL CYA Test Tablets
PLR145/50
50pk
DBNPA (Liquids)
0 – 13 ppm 065 PL
PL DPD No1 A Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
PL DPD No 3 C Solution
PLR104
30ml
DBNPA (Tablets)
0 – 13 ppm 082 PL
PL DPD No1 Tablets
PLR141/50
50pk
PL DPD No3 Tablets
PLR142/50
50pk
DEHA (Liquids)
 –  20 – 1000 ppb 021 PL
PL Oxygen Scavenger No1 Solution
PLR112
30ml
PL Oxygen Scavenger No2 Solution
PLR113
30ml
Erythorbic Acid
 – 0 – 3.5 ppm 070 PL
PL Oxygen Scavenger No1 Solution
PLR112
30ml
PL Oxygen Scavenger No2 Solution
PLR113
30ml
Fluoride (Liquids)
F  0 – 2 ppm 072 PL
PL Fluoride No1 Solution
PLR114
65ml
PL Fluoride No2 Solution
 PLR175
30ml
Hardness Total HR (Tablets)
CaCO3  20 – 500 ppm 057 PL
PL Total Hardness Tablets
PLR150/50
50pk
Hardness Total LR (Tablets)
CaCO3  2 – 50 ppm 056 PL
PL Total Hardness Tablets
PLR150/50
50pk
Hydrazine (Liquids)
N2H4 5 – 600 ppb 023 PL
PL Hydrazine No1 Solution
PLR115
65ml
Hydroquinone (Liquids)
C6H6O2 0 – 2.5 ppm 026 PL
PL Oxygen Scavenger No1 Solution
PLR112
30ml
PL Oxygen Scavenger No2 Solution
PLR113
30ml
Hydrogen Peroxide HR (Liquids)
H2O2  0 – 200 ppm 025 PL
PL Hydrogen Peroxide HR No1 Solution
PLR116
30ml
PL Hydrogen Peroxide HR No2 Solution
PLR117
30ml
Hydrogen Peroxide LR (Liquids)
 H2O2  0 – 3.8 ppm 066  PL
PL Hydrogen Peroxide LR No1 Solution
PLR152
30ml
PL Hydrogen Peroxide LR No2 Solution
PLR153
30ml
Hydrogen Peroxide LR (Tablets)
H2O2  0 – 3.8 ppm 024 PL
PL Hydrogen Peroxide LR Tablets
PLR214/50
50pk
Iodine (Liquids)
I2 0 – 28 ppm 067 PL
PL DPD No1 A Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
Iodine (Tablets)
I2 0 – 28 ppm 027 PL
PL DPD No1 Tablets
PLR141/50
50pk
Iron HR (Liquids)
Fe  0 – 30 ppm 030  PL
PL Iron HR No1 Solution
PLR119
65ml
PL Iron HR No2 Solution
PLR120
30ml
Iron LR (Tablets)
Fe  0 – 1 ppm 028 PL
PL Iron LR Tablets
PLR151/50
50pk
Iron MR (Powder)
Fe  0 – 10 ppm 029 PL
PL Iron MR 1 Powder
PLR118
20g
Iron MR Ferrous (Powder)
Fe  0 – 10 ppm 127 PL
PL Iron MR 2 Powder
PLR241
20g
Magnesium (Tablets)
 Mg 0 – 100 ppm 093  PL
PL Magnesium Tablets
PLR212/50
50pk
Manganese LR (Tablets)
Mn 0.2 – 5 ppm 031  PL
PL Manganese LR No1 Tablets
PLR201/50
50pk
PL Manganese LR No2 Tablets
PLR202/50
50pk
Methylethylketoxime (Liquid)
0 – 4.1 ppm 069 PL
PL Oxygen Scavenger No1 Solution
PLR112
30ml
PL Oxygen Scavenger No2 Solution
PLR113
30ml
Molybdate HR (Liquids)
MoO4 5 – 200 ppm 033 PL
PL Molybdate No1 Solution
PLR121
65ml
Molybdate HR (Tablets)
MoO4 1 – 100 ppm 032 PL
PL Molybdate HR No1 Tablets
PLR162/50
50pk
PL Molybdate HR No2 Tablets
PLR163/50
50pk
Molybdate LR (Tablets)
MoO4 0 – 15 ppm 096 PL
PL Molybdate LR No1 Tablets
PLR199/50
50pk
PL Molybdate LR No2 Tablets
PLR200/50
50pk
Nickel HR (Liquids)
Ni 0 – 10 ppm 100 PL
PL Nickel HR No1 Powder
PLR178
50g
PL Nickel HR No2 Solution
PLR179
65ml
PL Nickel HR No3 Powder
PLR180
20g
Nickel HR (Tablets)
Ni 0 – 7 ppm 090 PL
PL Nickel HR No1 Tablets
PLR225/50
50pk
PL Nickel LR No2 Tablets
PLR226/50
50pk
Nitrate (Powder)
N 0 – 11 ppm 034 PL
PL Nitrate No1 Powder
PLR233
20g
PL Nitrate No2 Solution
PLR234
65ml
Nitrite HR (Liquids)
NaNO2 0 – 3000 ppm 101 PL
PL Nitrite HR No2 Solution
PLR184
65ml
Nitrite LR (Tablets)
 NaNO2 0 – 0.5 ppm 035 PL
PL Nitrite LR Tablets
PLR168/50
50pk
Ozone (Liquids)
O3 0 – 5.4 ppm 092 PL
PL DPD No1 A Solution
PLR102
30ml
PL DPD No1 B Solution
PLR103
30ml
PL DPD No3 C Solution
PLR104
30ml
PL DPD Glycine Solution
PLR106
30ml
Ozone (Tablets)
O3 0 – 5.4 ppm 037 PL
PL DPD No1 Tablets
PLR141/50
50pk
PL DPD No3 Tablets
PLR142/50
50pk
PL DPD Glycine Solution
PLR106
30ml
Phenol (Tablets)
 C6H5OH 0 – 5 pm 098 PL
PL Phenol No1 Tablets
PLR215/50
50pk
PL Phenol No2 Tablets
PLR216/50
50pk
PL Phenol PR Tablets
PLR217/50
50pk
pH MR (Liquids)
pH 6.4 – 8.4 pH 039 PL
PL pH 6.4 – 8.4 Solution
PLR125/50
30ml
pH MR (Tablets)
pH 6.4 – 8.4 pH 038 PL
PL Phenol Red Tablets
PLR147/50
50pk
Phosphate HR (Liquids)
PO4 0 – 100 ppm 047 PL
PL Phosphate HR No1 Solution
PLR129
65ml
PL Phosphate HR No2 Solution
PLR130
65ml
Phosphate LR (Liquids)
PO4 0 – 4 ppm 045 PL
PL Phosphate LR No1 Solution
PLR127
65ml
PL Phosphate LR No2 Powder
PLR128
10g
Phosphate LR (Tablets)
PO4 0 – 4 ppm 044 PL
PL Phosphate LR No1 Tablets
PLR191/50
50pk
PL Phosphate LR No2 Tablets
PLR192/50
50pk
pH Universal (Liquids)
pH  4 – 11 pH  042  PL
PL pH 4 – 11 Solution
PLR126
65ml
pH Universal (Tablets)
 pH 5 – 11 pH  041  PL
PL Universal pH Tablets
PLR194/50
50pk
Polyacrylate (Liquids)
1 – 30 ppm 085 PL
PL Polyacrylate No1 Solution
PLR139
65ml
PL Polyacrylate No2 Solution
PLR140
65ml
Potassium (Tablets)
K 0.7 – 12 ppm 048 PL
PL Potassium Tablets
PLR228/50
50pk
Silica HR (Powder)
SiO2 0 – 100 ppm 050 PL
PL Silica HR No1 Powder
PLR134
20g
PL Silica HR No2 Solution
PLR135
60g
PL Silica HR No3 Solution
PLR136
40g
Silica LR (Liquids)
SiO2 0 – 5 ppm 049 PL
PL Silica LR No3 Powder
PLR133
40g
PL Silica LR No1 Solution
PLR131
65ml
PL Silica LR No2 Solution
PLR132
65ml
Sodium Hypochlorite (Liquids)
NaOCl 0.2 – 40 % 068 PL
PL Chlorine HR No1 Solution
PLR109
30ml
PL Chlorine HR No2 Solution
PLR110
30ml
Sodium Hypochlorite (Tablets)
 NaOCl 0.2 – 40% 051 PL
PL Chlorine HR Tablets
PLR64/50
50pk
PL Acidifying GP Tablets
PLR208/50
50pk
Sulphate (Powder)
 SO4 0 – 100 ppm 055 PL
PL Sulphate No1 Powder
PLR137
10g
Sulphate (Tablets)
SO4 5 – 100 ppm 054 PL
PL Sulphate Tablets
PLR160/50
50pk
Sulphite HR (Tablets)
NA2SO3 0 – 300 ppm 105 PL
PL Sulphite HR No1 Tablets
PLR203/50
50pk
PL Sulphite HR No2 Tablets
PLR204/50
50pk
Suspended Solids
0 – 750 ppm 081
PL
No Reagents
Tannic Acid (Liquids)
0 – 150 ppm 91 PL
PL Tannin No 1 Solution
PLR176
65ml
PL Tannin No 2 Solution
PLR177
30ml
Total Oxidant (Liquids)
CL2 0 – 8 ppm  108  PL
PL DPD No 1 A Solution
 PLR102  30ml
PL DPD No 1 B Solution
  PLR103  30ml
PL DPD No 3 C Solution
  PLR104  30ml
PL DPD Acidifying Solution
  PLR105  30ml
PL DPD Neutralising Solution
  PLR107  30ml
Transmission 420nm 
0 – 100% 114  PL
No Reagents
Transmission 470nm
0 – 100% 115  PL
No Reagents
Transmission 520nm
0 – 100% 116  PL
No Reagents
Transmission 570nm 
0 – 100% 117  PL
No Reagents
Transmission 620nm
0 – 100% 118  PL
No Reagents
Transmission 670nm
0 – 100% 119  PL
No Reagents
Turbidity
0 – 1000 FAU 059  PL
No Reagents
Urea
CO(NH2)2 0.1 – 2.5 ppm 120  PL
PL Urea Reagent 1
 PLR239  30ml
PL Urea Reagent 2
 PLR240  10ml
PL Ammonia No 1 Tablets
 PLR195/50  50pk
PL Ammonia No 2 Tablets
 PLR196/50  50pk
Zinc (Tablets)
 Zn 0 – 1 ppm 062 PL
PL Copper/Zinc LR Tablets
PLR161/50
50pk
PL EDTA Tablets
PLR190/50
50pk

Note: Ranges vary and are dependant on the sample size used to carryout the test, for more information please read the instructions.

PRIMELAB 1.0 PHOTOMETER

Posted by admin

NOW SOLD OUT, PRIMELAB 2.0 AVAILABLE SOON

PrimeLabmain_500x500

KEY FEATURES

    • Expandable parameter list.
    • Wireless Bluetooth connection.
    • Calibration by user.
    • One time “blank” per session.
    • Simple to use PC software.

ONE SENSOR, ALL PARAMETERS

The “PrimeLab 1.0 Multitest” is a photometer of the latest generation. With only one light source and the JENCOLOR multi-spectral sensor used exclusively in the PrimeLab, it is possible to measure all water parameters where the water sample is visibly discoloured after addition of a reagent. The excellent accuracy of the JENCOLOR sensor even allows self-calibration of the system at the press of a button.

APPLICATIONS

The PrimeLab Photometer is used in a wide range of water testing applications including Industrial water treatment, Boiler, cooling and closed system analysis, Process water, Pre-treatment plant, Effluent plant, Laboratories and Mobile applications.

PHOTOMETER “A LA CARTE”

Each PrimeLab can be configured individually. Choose one of the usual parameter combinations, such as 3-in-1, 5-in-1 … or select from the parameter list only those parameters that you want activated on your PrimeLab. You also have the option of enabling additional parameters on the device at a later date by acquisition of an appropriate code.

DESKTOP ASSISTANT

With the ”PrimeLab Desktop Assistant” software which comes included in the PrimeLab package, the measurement results can be managed and evaluated in object-oriented fashion with little effort. After saving the details of your water treatment chemicals, it is even possible to print measurement-related dosage recommendations. Furthermore, the software allows convenient remote control of the PrimeLab as well as subsequent activation of additional parameters/measuring methods on the photometer. Via the automatic update feature, both the software and the PrimeLab are permanently kept up to date.

Bluetooth® wireless connection

In addition, the “PrimeLab 1.0 Multitest” connects wirelessly via Bluetooth® to your Windows PC and the included software, as quickly and easily as you know it from your smartphone in your car.

For enquiries please email:
dtk@primelab.com

For a full list of avaiable parameters click here.

TECHNICAL SPECIFICATION

PARAMETER
SPECIFICATION
Spectical Range:
380 nm – 780 nm Complete coverage by JENCOLOR multi-spectral sensor
Data Transmission:
Built-in Bluetooth® module with free Bluetooth® USB dongle included
Calibration:
Auto-calibration by JENCOLOR sensor; determination of LED brightness
One Time Zero:
Intelligent OTZ function, detecting different zero types
Internal Memory:
100 data records / 20 account records100 data records/20 account records – Unlimited via PrimeLab software
Clock / Date:
RTC (real-time clock) with date function
Auto-off:
Factory default = 10 minutes. Individually adjustable
Menu Navigation:
Intuitive, display-controlled 4-button menu system, test instructions during the measurement process
Power Supply:
Optional 4 x AAA batteries or 100 – 240 V AC
Display:
Graphical LCD display, monochrome
Operating Languages:
German, English, Spanish, French
Additional languages currently under development
Environment
5 – 45°C (41 – 113°F) / 30 – 90% RH
Water Resistance
The unit is splash-proof
Reagents:
The calibration curves of the individual parameters are matched to the reagents offered by the manufacturer. Use of reagents by other manufacturers may result in measurement errors. The scope of delivery of the PrimeLab includes solely high-quality reagents “Made in Germany” and “Made in the UK”!
Optics
Supplied by JENCOLOR
Dimensions
175mm x 88mm x 59mm
Weight:
160g

DESKTOP ASSISTANT

Posted by admin

 

freedownloadbutton

 

PrimeLabmain_100x100

ACCOUNT / TEST RESULT MANAGEMENT

    • Define any number of “accounts” (addresses, measuring sources with volume specifications, etc).
    • Each measurement performed with the PrimeLab is assigned to such an “account.
    • Transfer of 20 “Accounts” to the PrimeLab per mouse click.
    • Synchronization of measurement data between the PrimeLab and the “PrimeLab Desktop Assistant”.
    • Convenient reporting function for printing results; account-related, selected by date and / or parameter.

DOSE RECOMMENDATION

    • You can input the water treatment chemicals that you use and ideal ranges for each parameter you can get dosage recommendations calculated, view them and print them.
    • Store your individually used water treatment chemicals (e.g. “pH Minus”).
    • Store ideal ranges for each measurement parameter (e.g. “pH 7.2 – 7.4”).
    • Monitor controlled environment areas such as freezers, storage areas and other critical areas.
    • Store humidity and temperature historical data for report generation.
software 1
 softwarescreen500x500

PARAMETER-MANAGEMENT / REMOTE CONTROL

    • Subsequent uploading of additional parameters on the PrimeLab by entering a code into the software.
    • Remote control of the PrimeLab.
    • Overview of all methods of measurement with display of measurement ranges and stored ideal ranges.
    • Definition of customized ideal ranges per parameter.

SET-UP / GLOSSARY / SUPPORT

    • Update of the PrimeLab firmware and the “PrimeLab Desktop Assistant” software by mouse click.
    • Personalisation of the PrimeLab / individual naming of your machine.
    • Setting date and time / Internet access / reset to factory default values.
    • Networking with other users via the forum on www.PrimeLab.org.
    • Extensive information on water per parameter in the section “Glossary”.
    • Connection of multiple PrimeLabs to the software.
 PDA Test Report500x500

WIRELESS CONNECTIVITY VIA BLUETOOTH®

The PrimeLab is equipped with a Bluetooth® module and connects automatically with the user’s PC, in the same way as smartphones connect to a car kit. In addition, the PrimeLab can be controlled by its own software, the “PrimeLab Desktop Assistant”.

ACCOUNTS

The free “PrimeLab Desktop Assistant” software permits storage of address data (accounts) with information on the sample water origin (e.g. “50 m³ pool”).

EVALUATIONS / DOSAGE RECOMMENDATIONS

Calculated water values, which are always assigned to “accounts”, can be managed historically, printed, compared and interpreted. Additionally, the software recommends the dosage for the individual water treatment chemicals (if the details for which have been entered into the appropriate account), in order to restore ideal water parameters. The user can individually set the range of “ideal water values”, too, for each parameter.

ONLINE UPDATES AND SUBSEQUENT ACTIVATION OF PARAMETERS

Via the “PrimeLab Desktop Assistant” software and an existing internet connection both the software and the firmware can be updated at the press of a button. Even if additional parameters are required at later date, this is very easily possible by purchase of a code and subsequent activation via the software.

freedownloadbutton

GASTECH TUBES & SAMPLING PUMPS

Posted by admin
tubes300x300 gastechtube1000-665

KEY FEATURES

    • Quick, Accurate & Simple to use.
    • Cost effective method of gas detection and air sampling.
    • Capacity to detect over 600 different gasses.
    • Clear & precise easy to read colour change.
    • Easy to use sample pump requires minima lstrokes.
    • Pump adapter to provide convenient, one handed operation.
    • Gastec Tubes are used as a cost-effective short term or long term detection method worldwide in;
      • Determining and measuring concentration peaks.
      • Measuring personal exposure in the inhalation area.
      • Detecting leaks in pipelines, gas installations etc.
      • Air analysis in sewers, shafts and confined spaces.

Applications Include;

  • Workplace air,
  • Emission measurements,
  • Quality control,
  • Process control,
  • Monitoring of compressed air for breathing apparatus,
  • Environmental and hazardous substance detection applications.

GASTEC TUBES

Gas detector tubes are glass tubes that are filled with a chemical reagent that absorbs and reacts with the target gas or vapour being measured. A chromogenic stain (a colour change) is created. For most tubes, the concentration is read directly from the pinpoint accurate measurement scale on each tube. This makes this form of monitoring ideal for spot sampling as it can be more accurate then electronic gas detectors. The Gastec detector tube system is comprised of a handheld Gastec air sampling pump and Gastec detector tubes.

GAS SAMPLING PUMP

The Gastec Sampling Pump offers superior benefits over other tube sampling techniques.

  • Easy to use and minimal effort often using single pump strokes
  • Complete with a tube tip breaker.
  • Flow finish indicator to show when pump stroke is complete.
  • Optional sample counter.
pumphandpump
GAS OR VAPOUR TO BE MEASURED
CHEMICAL FORMULA
ORDER CODE
MEASURING RANGE (PPM)
SHELF LIFE (YEARS)
PACK SIZE
Gastec Sampling Pump GV-100S ea
Gastec Sampling Pump With Counter GV-110S ea
Benzene C6H6 GAS121L 0.1 – 65 3 10
Carbon Dioxide CO2 GAS2LL 300 – 5000 3 10
Carbon Monoxide CO
GAS1LC 1 – 30 2 10
Formaldehyde HCHO GAS91LL 0.05 – 1 1 10
Ozone O3 GAS18L 0.025 – 3 3 10
Note: Other gasses are available upon request.

SPER 850081 – MULTI PARAMETER WATER QUALITY METER

Posted by admin

Spermultimeter1000x1000

sperphprobe200x200
pH Probe

KEY FEATURES

    • Meter can be enabled to measure a range of parameters by ordering the appropriate probe.
    • Interchangeable probes enable the meter to read;
      • pH,
      • mV,
      • Conductivity,
      • Total Dissolved Solids,
      • Dissolved Oxygen,
      • Temperature,
      • ORP.
    • Interchangeable probes make the meter versatile and convenient.
    • Intelligent probes electronically retain calibration information.
    • No calibration is required when changing probes.
    • Automatic Temperature Compensation.
    • Auto shut off, Hold, min/max.
    • RS232 port enables computer connectivity.
    • Large LCD screen.
    • Fold-out easel back and tripod.
    • Only weighs 204g.

MULTI PARAMETER WATER QUALITY METER

Using interchangeable probes, this versatile meter reads pH, mV, Conductivity, TDS, Dissolved Oxygen, Temperature and ORP. Intelligent probes electronically retain calibration information. No recalibration is required when changing probes. The display simultaneously reads temperature in user selectable °C & °F, and all measurements are automatically temperature compensated. RS232 port enables communication with a computer.

 sperdoprobe250x250Dissolved Oxygen Probe
When ordering the meter is completely customisable and can be ordered with one or any number of the different probes. The meter also features an auto power off, hold, min/max, fold-out easel back and a tripod screw. It comes with a 9V battery supplied.

CALIBRATION SOLUTIONS

Each meter is supplied with a certificate of conformity which is valid for 12 months.All types of meters can be sent to our laboratory for an annual calibration which is valid for 12 months.

ORDERING INFORMATION

ORDER CODE
DESCRIPTION
PACK SIZE
850081
Sper Multi Parameter Meter
ea
840016
pH probe
ea
850084
Conductivity / TDS probe
ea
850082
ATC probe
ea
840049
Spear Tip pH Probe
ea
850088
ORP Probe
ea
850083
Conductivity Probe
ea
850087
Dissolved Oxygen Probe
ea
SDT109
1413 µS Conductivity Solution
65ml
SDT119
pH 4 Buffer Solution
65ml
SDT118
pH 7 Buffer Solution
65ml
SDT161
pH 10 Buffer Solution
65ml
840057
RS232 Cable
ea
850080
Intelligent Software
ea

TECHNICAL SPECIFICATION

PARAMETER
SPECIFICATION
PH PROBE
pH Range:
0 ~ 14 pH
Resolution:
0.01 pH
Accuracy:
±(0.02pH + 2d)
CONDUCTIVITY PROBE
Conductivity Range:
0.2 ~ 1.999 / 2 ~ 19.99
Resolution:
0.001 / 0.01
Accuracy:
±(3%fs + 1d)
Temperature Range:
0 ~ 60°C / 32 ~ 140°F
Resolution:
0.1
Accuracy:
0.8 / 1.5
CONDUCTIVITY/TDS PROBE
Conductivity Range:
0.2 ~ 2.000 / 2 ~ 19.99
Resolution:
0.001 / 0.01
Accuracy:
±(3%fs + 1d)
TDS Range:
132 ~ 1320 / 1320 ~ 13200
Resolution:
1 / 10
Accuracy:
±(3%fs + 1d)
Temperature Range:
0 ~ 60°C / 32 ~ 140°F
Resolution:
0.1
Accuracy:
0.8 / 1.5
DISSOLVED OXYGEN PROBE
Dissolved Oxygen Range:
0 ~ 20 mg/L
Resolution:
0.1
Accuracy:
±0.4
Temperature Range:
0 ~ 50°C / 32 ~ 122°F
Resolution:
0.1
Accuracy:
0.8 / 1.5
ATC PROBE
Temperature Range:
0 ~ 65°C / 32 ~ 149°F
Resolution:
0.1 °C/°F
Accuracy:
±0.8 / ±1.5
SPEAR TIP PH PROBE
pH Range:
0 ~ 14 pH
Resolution:
0.01 pH
Accuracy:
±(0.02pH + 2d)
ORP PROBE
ORP Range:
0 ~ 1999 Mv
Resolution:
1 Mv
Accuracy:
±(0.5% + 2d)
METER
Dimensions:
203 x 70 x 25 mm (L x W x H)
Weight:
204g

 

 

EXTECH EA10P – DUAL K TYPE THERMOMETER

Posted by admin
EA10600x600

KEY FEATURES

    • Compact and rugged design features large backlit display.
    • Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2].
    • Selectable units of °F, °C, K (Kelvin).
    • Wide temperature range with 0.1°/1° resolution.
    • Timer function displays elapsed time plus the time when MIN and MAX readings are taken.
    • Data Hold function freezes reading on display.
    • Auto Power off to save battery life.
    • Low battery and overrange indication.
    • Records Max/Min readings for later recall.
    • Complete with built-in stand, protective holster, two Type K bead wire temperature probes and 6 AAA batteries.
    • Basic Type K Dual input.
    • OFFSET key used for zero function to make relative measurements.

EA10P – EXTECH DUAL K TYPE THERMOMETER

The Dual K Type Thermometer is a digital device with capability of displaying temperature readings in °C or °F. Any kind of K-mode thermocouple can be adopted as the temperature transducer to measure Centigrade and Fahrenheit degrees, and also the temperature difference (double channel thermometer).

ORDERING INFORMATION

ORDER CODE
DESCRIPTION
EA10P
Extech Dual K Type Thermometer

TECHNICAL SPECIFICATION

PARAMETER
SPECIFICATION
Temperature 
Range:

-200°C – 1360°C

(-200°F – 1999°F)

Resolution:

0.1°C

(0.1°F)

Accuracy:
±(0.3% + 1°C / 2°F)
Meter
Power:
6 AAA batteries (supplied)
Dimensions:
152 x 72 x 37mm (L x W x H)
Weight:
235g

EXTECH RH520A – HUMIDITY & TEMP DATALOGGER

Posted by admin
RH520400x400
RH520(2)350X350

KEY FEATURES

    • Best value graphical datalogger in the market.
    • User friendly, easy to set up and operate.
    • Simultaneous numerical and graphical display of Humidity and Temperature readings, plus Time and Date.
    • Measures Humidity (10 to 95% RH) and Temperature (-20.0°F to 140.0°F) plus included LabVIEW™-based software calculates and graphs Dew Point, Wet Bulb, and GPP (grains per pound).
    • Large dual graphical LCD displays with adjustable vertical and horizontal TAC resolution.
    • Internal memory records up to 49,000 data points and can be transferred to a PC via RS-232 serial port for further data analysis.
    • LCD indicates percentage of memory remaining.
    • Replaceable probe does not require recalibration.
    • Detachable probe extends up to 1 meter for measurements in closed environments.
    • Audible and visual alarm with Hi/Low setpoints.
    • Output socket used with optional external alarm module.
    • Scroll the cursor to display selected data recorded.
    • Desk or wall mount.
    • Complete with built-in stand, detachable probe with 3ft (1m) cable, RS232 cable, RS-232 To USB Adaptor, LabView-based PC software, 100-240VAC 50/60Hz adaptor, and 3 AA batteries.
    • Weighs only 357g.

APPLICATIONS OF THE RH520A

    • Monitor and record Laboratory or clean Room temperature and humidity history.
    • Record process conditions.
    • Generate warning when conditions are outside required limits.
    • Monitor controlled environment areas such as freezers, storage areas and other critical areas.
    • Store humidity and temperature historical data for report generation.

EXTECH RH520A – GRAPHICAL DATALOGGER

Easy-to-operate digital recorder monitors and records temperature and humidity data in laboratories, storage and cleanrooms, freezers, and other critical areas. The detachable temperature/humidity probe extends up to one meter—ideal for measurements in closed environments. Probe does not require any calibration.

The large dual-graphic LCD simultaneously displays temperature (°F/°C) and relative humidity readings, plus time, date, battery status, and % of remaining memory. Dew point is easily displayed by pressing the dew point button. LCD also features adjustable vertical and horizontal resolution. Internal memory records up to 49,000 data points which can be transferred to a PC via RS-232 serial port for further analysis.

Audible and visual alarms generate warnings when conditions are outside selected high and low limits. A push-button lockout security feature prevents unauthorized tampering with settings. Recorder fits on your benchtop or easily mount to the wall.

ORDERING INFORMATION

ORDER CODE
DESCRIPTION
RH520A-240
Relative Humidity & Temperature Graphical Datalogger

TECHNICAL SPECIFICATION

PARAMETER
SPECIFICATION
Relative Humidity Range:
10.0 – 95.0%
Temperature Range:
-20.0 – 140.0°F (-28.0 – 60.0°C)
Accuracy:
±3% Relative Humidity; ±1.8°F/±1°C
Dimensions:
129 x 195 x 22mm (H x W x L)
Weight:
357g
Power:
3 x AA batteries
DTK Water
14 Morris Close,
Park Farm Ind Est,
Wellingborough,
NN8 6XF, UK
T: +44 (0)1604 686995
F: +44 (0)1604 686997
E: info@dtkwater.com

DTK Water is a Lovibond® company